Compare commits
4 commits
14e8b539c6
...
1cee160cad
Author | SHA1 | Date | |
---|---|---|---|
Bruno BELANYI | 1cee160cad | ||
Bruno BELANYI | 7009315b66 | ||
Bruno BELANYI | 6355c9c84d | ||
Bruno BELANYI | 0587294ccf |
125
2022/d16/ex1/ex1.py
Executable file
125
2022/d16/ex1/ex1.py
Executable file
|
@ -0,0 +1,125 @@
|
|||
#!/usr/bin/env python
|
||||
|
||||
import dataclasses
|
||||
import functools
|
||||
import sys
|
||||
from collections import defaultdict
|
||||
|
||||
|
||||
@dataclasses.dataclass
|
||||
class Valve:
|
||||
flow: int
|
||||
neighbours: set[str]
|
||||
|
||||
|
||||
Graph = dict[str, Valve]
|
||||
DistanceMatrix = dict[str, dict[str, int]]
|
||||
|
||||
START_ROOM = "AA"
|
||||
|
||||
|
||||
def solve(input: list[str]) -> int:
|
||||
def to_graph(input: list[str]) -> Graph:
|
||||
res = {}
|
||||
|
||||
for line in input:
|
||||
assert line.startswith("Valve ") # Sanity check
|
||||
|
||||
name = line.split()[1]
|
||||
flow = line.split("=")[1].split(";")[0]
|
||||
neighbours = line.split(";")[1].replace(", ", " ").split()[4:]
|
||||
|
||||
res[name] = Valve(int(flow), set(neighbours))
|
||||
|
||||
return res
|
||||
|
||||
def useful_valves(g: Graph) -> set[str]:
|
||||
return {k for k, v in g.items() if v.flow > 0}
|
||||
|
||||
def floyd_warshall(g: Graph) -> DistanceMatrix:
|
||||
points = list(g.keys())
|
||||
|
||||
res: DistanceMatrix = defaultdict(dict)
|
||||
|
||||
for p in points:
|
||||
for n in g[p].neighbours:
|
||||
res[p][n] = 1
|
||||
|
||||
for p in points:
|
||||
for i in points:
|
||||
for j in points:
|
||||
if (ip := res[i].get(p)) is None:
|
||||
continue
|
||||
if (pj := res[p].get(j)) is None:
|
||||
continue
|
||||
dist = ip + pj
|
||||
if (ij := res[i].get(j)) is not None:
|
||||
dist = min(dist, ij)
|
||||
res[i][j] = dist
|
||||
|
||||
return res
|
||||
|
||||
def prune_distances(dist: DistanceMatrix, of_interest: set[str]) -> DistanceMatrix:
|
||||
# Only keep non-zero valves for our visits
|
||||
pruned = {
|
||||
i: {j: dist for j, dist in line.items() if j in of_interest}
|
||||
for i, line in dist.items()
|
||||
if i in of_interest
|
||||
}
|
||||
# Explicitly add the starting room, in case it was pruned
|
||||
pruned[START_ROOM] = {
|
||||
n: dist for n, dist in dist[START_ROOM].items() if n in of_interest
|
||||
}
|
||||
return pruned
|
||||
|
||||
def max_flow(g: Graph, dist: DistanceMatrix) -> int:
|
||||
def pressure_per_minute(opened_valves: frozenset[str]) -> int:
|
||||
return sum(g[valve].flow for valve in opened_valves)
|
||||
|
||||
@functools.cache
|
||||
def helper(start: str, time: int, opened_valves: frozenset[str]) -> int:
|
||||
assert time >= 0 # Sanity check
|
||||
if time == 0:
|
||||
return 0
|
||||
|
||||
pressure = pressure_per_minute(opened_valves)
|
||||
|
||||
# Base-case, don't do anything
|
||||
best = pressure * time
|
||||
|
||||
# Try to open the current valve if not done already
|
||||
if start not in opened_valves:
|
||||
best = max(
|
||||
best,
|
||||
helper(start, time - 1, opened_valves | {start}) + pressure,
|
||||
)
|
||||
|
||||
# Try to go to each neighbour
|
||||
for n, d in dist[start].items():
|
||||
if d >= time:
|
||||
continue
|
||||
best = max(
|
||||
best,
|
||||
helper(n, time - d, opened_valves) + pressure * d,
|
||||
)
|
||||
|
||||
return best
|
||||
|
||||
opened_valves = set()
|
||||
# If starting room has no flow, consider it open to reduce search space
|
||||
if g[START_ROOM].flow == 0:
|
||||
opened_valves.add(START_ROOM)
|
||||
return helper(START_ROOM, 30, frozenset(opened_valves))
|
||||
|
||||
graph = to_graph(input)
|
||||
dist = prune_distances(floyd_warshall(graph), useful_valves(graph))
|
||||
return max_flow(graph, dist)
|
||||
|
||||
|
||||
def main() -> None:
|
||||
input = sys.stdin.read().splitlines()
|
||||
print(solve(input))
|
||||
|
||||
|
||||
if __name__ == "__main__":
|
||||
main()
|
61
2022/d16/ex1/input
Normal file
61
2022/d16/ex1/input
Normal file
|
@ -0,0 +1,61 @@
|
|||
Valve WT has flow rate=0; tunnels lead to valves BD, FQ
|
||||
Valve UG has flow rate=0; tunnels lead to valves FQ, YB
|
||||
Valve FN has flow rate=0; tunnels lead to valves TV, GA
|
||||
Valve RU has flow rate=11; tunnels lead to valves YZ, QS, BL, BT, WJ
|
||||
Valve RH has flow rate=0; tunnels lead to valves AS, II
|
||||
Valve FL has flow rate=0; tunnels lead to valves HR, PQ
|
||||
Valve KQ has flow rate=18; tunnels lead to valves FR, BN
|
||||
Valve PM has flow rate=25; tunnels lead to valves YZ, FR
|
||||
Valve RQ has flow rate=0; tunnels lead to valves FQ, MW
|
||||
Valve BL has flow rate=0; tunnels lead to valves RU, IR
|
||||
Valve FF has flow rate=0; tunnels lead to valves QS, ED
|
||||
Valve KP has flow rate=0; tunnels lead to valves QM, MA
|
||||
Valve YB has flow rate=0; tunnels lead to valves UG, HR
|
||||
Valve TV has flow rate=17; tunnels lead to valves BD, MT, FN
|
||||
Valve HY has flow rate=0; tunnels lead to valves DW, IU
|
||||
Valve KF has flow rate=0; tunnels lead to valves AA, HR
|
||||
Valve YC has flow rate=0; tunnels lead to valves II, MA
|
||||
Valve EE has flow rate=0; tunnels lead to valves AA, CD
|
||||
Valve ED has flow rate=9; tunnels lead to valves HG, FF
|
||||
Valve SA has flow rate=0; tunnels lead to valves MW, LS
|
||||
Valve II has flow rate=20; tunnels lead to valves YC, CY, QP, RH
|
||||
Valve BN has flow rate=0; tunnels lead to valves BT, KQ
|
||||
Valve MO has flow rate=0; tunnels lead to valves XO, VI
|
||||
Valve YZ has flow rate=0; tunnels lead to valves RU, PM
|
||||
Valve WJ has flow rate=0; tunnels lead to valves RU, QP
|
||||
Valve AW has flow rate=0; tunnels lead to valves HR, DW
|
||||
Valve MJ has flow rate=0; tunnels lead to valves BP, AA
|
||||
Valve DW has flow rate=4; tunnels lead to valves AU, CB, HY, GL, AW
|
||||
Valve QM has flow rate=0; tunnels lead to valves KP, FQ
|
||||
Valve LF has flow rate=5; tunnels lead to valves LS, QN, AU, BP, ZY
|
||||
Valve QS has flow rate=0; tunnels lead to valves FF, RU
|
||||
Valve BT has flow rate=0; tunnels lead to valves BN, RU
|
||||
Valve VI has flow rate=22; tunnel leads to valve MO
|
||||
Valve LS has flow rate=0; tunnels lead to valves LF, SA
|
||||
Valve QD has flow rate=0; tunnels lead to valves HR, ZY
|
||||
Valve HG has flow rate=0; tunnels lead to valves AS, ED
|
||||
Valve BD has flow rate=0; tunnels lead to valves WT, TV
|
||||
Valve CD has flow rate=0; tunnels lead to valves EE, MW
|
||||
Valve QP has flow rate=0; tunnels lead to valves II, WJ
|
||||
Valve MW has flow rate=7; tunnels lead to valves PQ, SA, CB, CD, RQ
|
||||
Valve AU has flow rate=0; tunnels lead to valves DW, LF
|
||||
Valve RR has flow rate=0; tunnels lead to valves AS, MA
|
||||
Valve GA has flow rate=0; tunnels lead to valves FN, MA
|
||||
Valve MT has flow rate=0; tunnels lead to valves CY, TV
|
||||
Valve HR has flow rate=14; tunnels lead to valves KF, YB, QD, AW, FL
|
||||
Valve AS has flow rate=16; tunnels lead to valves RR, RH, HG, IR
|
||||
Valve CY has flow rate=0; tunnels lead to valves MT, II
|
||||
Valve AA has flow rate=0; tunnels lead to valves OX, KF, GL, MJ, EE
|
||||
Valve IU has flow rate=0; tunnels lead to valves XO, HY
|
||||
Valve XO has flow rate=23; tunnels lead to valves IU, MO
|
||||
Valve FR has flow rate=0; tunnels lead to valves KQ, PM
|
||||
Valve CB has flow rate=0; tunnels lead to valves MW, DW
|
||||
Valve ZY has flow rate=0; tunnels lead to valves QD, LF
|
||||
Valve BP has flow rate=0; tunnels lead to valves LF, MJ
|
||||
Valve QN has flow rate=0; tunnels lead to valves LF, FQ
|
||||
Valve IR has flow rate=0; tunnels lead to valves AS, BL
|
||||
Valve PQ has flow rate=0; tunnels lead to valves FL, MW
|
||||
Valve GL has flow rate=0; tunnels lead to valves AA, DW
|
||||
Valve OX has flow rate=0; tunnels lead to valves MA, AA
|
||||
Valve MA has flow rate=10; tunnels lead to valves RR, YC, GA, OX, KP
|
||||
Valve FQ has flow rate=12; tunnels lead to valves QN, WT, UG, RQ, QM
|
128
2022/d16/ex2/ex2.py
Executable file
128
2022/d16/ex2/ex2.py
Executable file
|
@ -0,0 +1,128 @@
|
|||
#!/usr/bin/env python
|
||||
|
||||
import dataclasses
|
||||
import functools
|
||||
import sys
|
||||
from collections import defaultdict
|
||||
|
||||
|
||||
@dataclasses.dataclass
|
||||
class Valve:
|
||||
flow: int
|
||||
neighbours: set[str]
|
||||
|
||||
|
||||
Graph = dict[str, Valve]
|
||||
DistanceMatrix = dict[str, dict[str, int]]
|
||||
|
||||
START_ROOM = "AA"
|
||||
|
||||
|
||||
def solve(input: list[str]) -> int:
|
||||
def to_graph(input: list[str]) -> Graph:
|
||||
res = {}
|
||||
|
||||
for line in input:
|
||||
assert line.startswith("Valve ") # Sanity check
|
||||
|
||||
name = line.split()[1]
|
||||
flow = line.split("=")[1].split(";")[0]
|
||||
neighbours = line.split(";")[1].replace(", ", " ").split()[4:]
|
||||
|
||||
res[name] = Valve(int(flow), set(neighbours))
|
||||
|
||||
return res
|
||||
|
||||
def useful_valves(g: Graph) -> set[str]:
|
||||
return {k for k, v in g.items() if v.flow > 0}
|
||||
|
||||
def floyd_warshall(g: Graph) -> DistanceMatrix:
|
||||
points = list(g.keys())
|
||||
|
||||
res: DistanceMatrix = defaultdict(dict)
|
||||
|
||||
for p in points:
|
||||
for n in g[p].neighbours:
|
||||
res[p][n] = 1
|
||||
|
||||
for p in points:
|
||||
for i in points:
|
||||
for j in points:
|
||||
if (ip := res[i].get(p)) is None:
|
||||
continue
|
||||
if (pj := res[p].get(j)) is None:
|
||||
continue
|
||||
dist = ip + pj
|
||||
if (ij := res[i].get(j)) is not None:
|
||||
dist = min(dist, ij)
|
||||
res[i][j] = dist
|
||||
|
||||
return res
|
||||
|
||||
def prune_distances(dist: DistanceMatrix, of_interest: set[str]) -> DistanceMatrix:
|
||||
# Only keep non-zero valves for our visits
|
||||
pruned = {
|
||||
i: {j: dist for j, dist in line.items() if j in of_interest}
|
||||
for i, line in dist.items()
|
||||
if i in of_interest
|
||||
}
|
||||
# Explicitly add the starting room, in case it was pruned
|
||||
pruned[START_ROOM] = {
|
||||
n: dist for n, dist in dist[START_ROOM].items() if n in of_interest
|
||||
}
|
||||
return pruned
|
||||
|
||||
def max_flow(g: Graph, dist: DistanceMatrix) -> int:
|
||||
def pressure_per_minute(opened_valves: frozenset[str]) -> int:
|
||||
return sum(g[valve].flow for valve in opened_valves)
|
||||
|
||||
@functools.cache
|
||||
def helper(
|
||||
start: str, time: int, opened_valves: frozenset[str]
|
||||
) -> tuple[int, frozenset[str]]:
|
||||
assert time >= 0 # Sanity check
|
||||
if time == 0:
|
||||
return 0, opened_valves
|
||||
|
||||
pressure = pressure_per_minute(opened_valves)
|
||||
|
||||
# Base-case, don't do anything
|
||||
best = pressure * time, opened_valves
|
||||
|
||||
# Try to open the current valve if not done already
|
||||
if start not in opened_valves:
|
||||
score, valves = helper(start, time - 1, opened_valves | {start})
|
||||
score += pressure
|
||||
best = max(best, (score, valves))
|
||||
|
||||
# Try to go to each neighbour
|
||||
for n, d in dist[start].items():
|
||||
if d >= time:
|
||||
continue
|
||||
score, valves = helper(n, time - d, opened_valves)
|
||||
score += pressure * d
|
||||
best = max(best, (score, valves))
|
||||
|
||||
return best
|
||||
|
||||
opened_valves = set()
|
||||
# If starting room has no flow, consider it open to reduce search space
|
||||
if g[START_ROOM].flow == 0:
|
||||
opened_valves.add(START_ROOM)
|
||||
score, valves = helper(START_ROOM, 26, frozenset(opened_valves))
|
||||
elephant_score, _ = helper(START_ROOM, 26, valves)
|
||||
elephant_score -= pressure_per_minute(valves) * 26 # Don't double count
|
||||
return score + elephant_score
|
||||
|
||||
graph = to_graph(input)
|
||||
dist = prune_distances(floyd_warshall(graph), useful_valves(graph))
|
||||
return max_flow(graph, dist)
|
||||
|
||||
|
||||
def main() -> None:
|
||||
input = sys.stdin.read().splitlines()
|
||||
print(solve(input))
|
||||
|
||||
|
||||
if __name__ == "__main__":
|
||||
main()
|
61
2022/d16/ex2/input
Normal file
61
2022/d16/ex2/input
Normal file
|
@ -0,0 +1,61 @@
|
|||
Valve WT has flow rate=0; tunnels lead to valves BD, FQ
|
||||
Valve UG has flow rate=0; tunnels lead to valves FQ, YB
|
||||
Valve FN has flow rate=0; tunnels lead to valves TV, GA
|
||||
Valve RU has flow rate=11; tunnels lead to valves YZ, QS, BL, BT, WJ
|
||||
Valve RH has flow rate=0; tunnels lead to valves AS, II
|
||||
Valve FL has flow rate=0; tunnels lead to valves HR, PQ
|
||||
Valve KQ has flow rate=18; tunnels lead to valves FR, BN
|
||||
Valve PM has flow rate=25; tunnels lead to valves YZ, FR
|
||||
Valve RQ has flow rate=0; tunnels lead to valves FQ, MW
|
||||
Valve BL has flow rate=0; tunnels lead to valves RU, IR
|
||||
Valve FF has flow rate=0; tunnels lead to valves QS, ED
|
||||
Valve KP has flow rate=0; tunnels lead to valves QM, MA
|
||||
Valve YB has flow rate=0; tunnels lead to valves UG, HR
|
||||
Valve TV has flow rate=17; tunnels lead to valves BD, MT, FN
|
||||
Valve HY has flow rate=0; tunnels lead to valves DW, IU
|
||||
Valve KF has flow rate=0; tunnels lead to valves AA, HR
|
||||
Valve YC has flow rate=0; tunnels lead to valves II, MA
|
||||
Valve EE has flow rate=0; tunnels lead to valves AA, CD
|
||||
Valve ED has flow rate=9; tunnels lead to valves HG, FF
|
||||
Valve SA has flow rate=0; tunnels lead to valves MW, LS
|
||||
Valve II has flow rate=20; tunnels lead to valves YC, CY, QP, RH
|
||||
Valve BN has flow rate=0; tunnels lead to valves BT, KQ
|
||||
Valve MO has flow rate=0; tunnels lead to valves XO, VI
|
||||
Valve YZ has flow rate=0; tunnels lead to valves RU, PM
|
||||
Valve WJ has flow rate=0; tunnels lead to valves RU, QP
|
||||
Valve AW has flow rate=0; tunnels lead to valves HR, DW
|
||||
Valve MJ has flow rate=0; tunnels lead to valves BP, AA
|
||||
Valve DW has flow rate=4; tunnels lead to valves AU, CB, HY, GL, AW
|
||||
Valve QM has flow rate=0; tunnels lead to valves KP, FQ
|
||||
Valve LF has flow rate=5; tunnels lead to valves LS, QN, AU, BP, ZY
|
||||
Valve QS has flow rate=0; tunnels lead to valves FF, RU
|
||||
Valve BT has flow rate=0; tunnels lead to valves BN, RU
|
||||
Valve VI has flow rate=22; tunnel leads to valve MO
|
||||
Valve LS has flow rate=0; tunnels lead to valves LF, SA
|
||||
Valve QD has flow rate=0; tunnels lead to valves HR, ZY
|
||||
Valve HG has flow rate=0; tunnels lead to valves AS, ED
|
||||
Valve BD has flow rate=0; tunnels lead to valves WT, TV
|
||||
Valve CD has flow rate=0; tunnels lead to valves EE, MW
|
||||
Valve QP has flow rate=0; tunnels lead to valves II, WJ
|
||||
Valve MW has flow rate=7; tunnels lead to valves PQ, SA, CB, CD, RQ
|
||||
Valve AU has flow rate=0; tunnels lead to valves DW, LF
|
||||
Valve RR has flow rate=0; tunnels lead to valves AS, MA
|
||||
Valve GA has flow rate=0; tunnels lead to valves FN, MA
|
||||
Valve MT has flow rate=0; tunnels lead to valves CY, TV
|
||||
Valve HR has flow rate=14; tunnels lead to valves KF, YB, QD, AW, FL
|
||||
Valve AS has flow rate=16; tunnels lead to valves RR, RH, HG, IR
|
||||
Valve CY has flow rate=0; tunnels lead to valves MT, II
|
||||
Valve AA has flow rate=0; tunnels lead to valves OX, KF, GL, MJ, EE
|
||||
Valve IU has flow rate=0; tunnels lead to valves XO, HY
|
||||
Valve XO has flow rate=23; tunnels lead to valves IU, MO
|
||||
Valve FR has flow rate=0; tunnels lead to valves KQ, PM
|
||||
Valve CB has flow rate=0; tunnels lead to valves MW, DW
|
||||
Valve ZY has flow rate=0; tunnels lead to valves QD, LF
|
||||
Valve BP has flow rate=0; tunnels lead to valves LF, MJ
|
||||
Valve QN has flow rate=0; tunnels lead to valves LF, FQ
|
||||
Valve IR has flow rate=0; tunnels lead to valves AS, BL
|
||||
Valve PQ has flow rate=0; tunnels lead to valves FL, MW
|
||||
Valve GL has flow rate=0; tunnels lead to valves AA, DW
|
||||
Valve OX has flow rate=0; tunnels lead to valves MA, AA
|
||||
Valve MA has flow rate=10; tunnels lead to valves RR, YC, GA, OX, KP
|
||||
Valve FQ has flow rate=12; tunnels lead to valves QN, WT, UG, RQ, QM
|
Loading…
Reference in a new issue